ULP Series - Ultra Low Pressure Transmitters

Available: Out of Stock
Rs. 1.00

FEATURES

  • Ranges 0.125" W.C. to 1" W.C. (30 to 250 Pa)
  • Uni- or bi-directional pressure ranges 
  • Three selectable pressure ranges for each W.C. & Pa. (Analog)
  • Two jumper selectable pressure ranges for BACnet
  • 24 Vac/dc power supply standard
  • Available options include an LCD display and a relay output (Included on BACnet model)

APPLICATIONS

  • HVAC/VAV
  • Process Control
  • Air Flow Monitoring
  • Static Building Pressure
  • Drop Across Air Filters
  • Room Pressure Monitoring

DESCRIPTION
The ULP Ultra Low Pressure Transmitter is used to measure differential pressure in the ranges of 0.125"W.C. to 1"W.C. (30 to 250 Pa). It combines precision high sensitivity silicon sensing capabilities and the latest ASIC technology with Dynamic Self Compensation to substantially reduce offset errors due to changes in temperature, stability to warmup, long term instability and position sensitivity. It is ideal for monitoring pressure for air and other clean inert gas and is limited only to those media which will not attack silicon, nylon and epoxy adhesive.

The ULP features a selectable uni- or bi-directional pressure range and output signal types for the most flexible applications. An optional on-board relay output, which is field adjustable, allows for an alarm function as well as an LCD (Alarm relay and LCD are standard on BACnet model).

FEATURES

  • Ranges 0.125" W.C. to 1" W.C. (30 to 250 Pa)
  • Uni- or bi-directional pressure ranges 
  • Three selectable pressure ranges for each W.C. & Pa. (Analog)
  • Two jumper selectable pressure ranges for BACnet
  • 24 Vac/dc power supply standard
  • Available options include an LCD display and a relay output (Included on BACnet model)

APPLICATIONS

  • HVAC/VAV
  • Process Control
  • Air Flow Monitoring
  • Static Building Pressure
  • Drop Across Air Filters
  • Room Pressure Monitoring

DESCRIPTION
The ULP Ultra Low Pressure Transmitter is used to measure differential pressure in the ranges of 0.125"W.C. to 1"W.C. (30 to 250 Pa). It combines precision high sensitivity silicon sensing capabilities and the latest ASIC technology with Dynamic Self Compensation to substantially reduce offset errors due to changes in temperature, stability to warmup, long term instability and position sensitivity. It is ideal for monitoring pressure for air and other clean inert gas and is limited only to those media which will not attack silicon, nylon and epoxy adhesive.

The ULP features a selectable uni- or bi-directional pressure range and output signal types for the most flexible applications. An optional on-board relay output, which is field adjustable, allows for an alarm function as well as an LCD (Alarm relay and LCD are standard on BACnet model).

View Product Catalog

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).