WP Series - Gauge/Differential Liquid Pressure Transmitters
Categories
  • Same day Shipment
    for stock items
  • 100% Customer
    Satisfaction
  • 365 Days
    Support on Call
  • Payment
    Secure System
  • Only Best
    Brands

WP Series - Gauge/Differential Liquid Pressure Transmitters

Available: Out of Stock
Rs. 1.00

FEATURES

  • Excellent long-term stability and high accuracy
  • Backlit LCD for display of differential or gauge pressure 
  • Jumper selectable LCD backlight for low power consumption applications 
  • Four switch selectable pressure ranges 
  • Jumper selectable output types, 4-20 mA, 0-5 and 0-10 Vdc 
  • NEMA 4X (IP65) enclosure 
  • Pushbutton and remote zeroing terminal 
  • Uni-directional or bi-directional pressure range selection switch 
  • High / low port swap switch to solve incorrect plumbing for differential 
  • Normal or slow surge damping switch to prevent false alarms and reduce noise
  • Output polarity reverse switch 
Gauge pressure transmitter Wet/Wet differential pressure transmitter c/w LCD
Gauge pressure transmitter Wet/Wet differential 
pressure transmitter c/w LCD


APPLICATIONS

  • Pump Monitoring
  • Filter Monitoring
  • Chiller Monitoring 
  • HVAC Systems 

DESCRIPTION
The Wet-Wet pressure transmitter is designed with dual sensors that enable it to accept high differential pressures in the ranges of 5PSI to 500PSI. All models can handle overload pressure 2X the maximum full scale range and burst pressure is 5X the maximum full scale range.

The gage pressure transmitter is designed with a single sensor that enables it to accept high pressures in the ranges of 5PSI to 500PSI. All models can handle overload pressure 2X the maximum full scale range and burst pressure is 5X the maximum full scale range.

Features include field selectable pressure ranges and output signal types for the most flexible applications. Typical HVAC applications include monitoring of water differential and gage pressure. The output signal is factory calibrated and temperature compensated for the highest start-up accuracy.

Ensure that the maximum individual port pressure does not exceed the maximum pressure range of the unit. For example, the maximum individual port pressure on a WPD-102 is 100 PSI. Exceeding this may damage the sensors and WILL give erroneous readings. 

FEATURES

  • Excellent long-term stability and high accuracy
  • Backlit LCD for display of differential or gauge pressure 
  • Jumper selectable LCD backlight for low power consumption applications 
  • Four switch selectable pressure ranges 
  • Jumper selectable output types, 4-20 mA, 0-5 and 0-10 Vdc 
  • NEMA 4X (IP65) enclosure 
  • Pushbutton and remote zeroing terminal 
  • Uni-directional or bi-directional pressure range selection switch 
  • High / low port swap switch to solve incorrect plumbing for differential 
  • Normal or slow surge damping switch to prevent false alarms and reduce noise
  • Output polarity reverse switch 
Gauge pressure transmitter Wet/Wet differential pressure transmitter c/w LCD
Gauge pressure transmitter Wet/Wet differential 
pressure transmitter c/w LCD


APPLICATIONS

  • Pump Monitoring
  • Filter Monitoring
  • Chiller Monitoring 
  • HVAC Systems 

DESCRIPTION
The Wet-Wet pressure transmitter is designed with dual sensors that enable it to accept high differential pressures in the ranges of 5PSI to 500PSI. All models can handle overload pressure 2X the maximum full scale range and burst pressure is 5X the maximum full scale range.

The gage pressure transmitter is designed with a single sensor that enables it to accept high pressures in the ranges of 5PSI to 500PSI. All models can handle overload pressure 2X the maximum full scale range and burst pressure is 5X the maximum full scale range.

Features include field selectable pressure ranges and output signal types for the most flexible applications. Typical HVAC applications include monitoring of water differential and gage pressure. The output signal is factory calibrated and temperature compensated for the highest start-up accuracy.

Ensure that the maximum individual port pressure does not exceed the maximum pressure range of the unit. For example, the maximum individual port pressure on a WPD-102 is 100 PSI. Exceeding this may damage the sensors and WILL give erroneous readings. 

View Product Catalog

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).