The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in use today and operates over a standard two-wire system. The measuring means is a piezoresistive sensor, which actually contains three sensors in one. It contains a differential pressure sensor, a temperature sensor, and a static pressure sensor. Microprocessor-based electronics provide higher spanturndown ratio, improved temperature and pressure compensation, and improved accuracy. The transmitter’s meter body and electronics housing resist shock, vibration, corrosion, and moisture. The electronics housing contains a compartment for the singleboard electronics, which is isolated from an integral junction box. The single-board electronics is replaceable and interchangeable with any other ST 3000 Series 100 or Series 900 model transmitters. Like other Honeywell transmitters, the ST 3000 features two-way communication and configuration capability between the operator and the transmitter through several Honeywell field-rated portable configuration devices, including the Smart Field Communicator (SFC) and the Multiple Communication Configurator (MC ToolKit). While both are made for in-field use, the MC Toolkit also can be ordered for use in intrinsically safe environments. The SCT 3000 Smartline® Configuration Toolkit provides an easy way to configure instruments using a personal computer. The toolkit enables configuration of devices before shipping or installation. The SCT 3000 can operate in the offline mode to configure an unlimited number of devices. The database can then be loaded down-line during commissioning.

Features
 Choice of linear or square root output conformity is a simple configuration selection.
 Direct digital integration with Experion PKS and other control systems provides local measurement accuracy to the system level without adding typical A/D and D/A converter inaccuracies.
 Unique piezoresistive sensor automatically compensates input for temperature and static pressure. Added “smart” features include configuring lower and upper range values, simulating accurate analog output, and selecting preprogrammed engineering units for display.
 Smart transmitter capabilities with local or remote interfacing means significant manpower efficiency improvements in commissioning, start-up, and ongoing maintenance functions.


Advanced Diagnostics
ST 3000 is now available for both HART® 6 and FoundationTM Fieldbus with advanced diagnostics that minimize unplanned plant outages, minimize maintenance costs and by providing the industry’s most reliable transmitter.
 Provide advanced warning of possible failure events and avoid costly shutdowns.
 Three levels of failure reporting
 Comprehensive list of on-board diagnostics (Ref. ST 3000 User manual with HART® 6, 34-ST-25-17 Rev: June 09 and FoundationTM Fieldbus option manual 34-ST-25-15 Rev: June 09)

Description
The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in use today and operates over a standard two-wire system. The measuring means is a piezoresistive sensor, which actually contains three sensors in one. It contains a differential pressure sensor, a temperature sensor, and a static pressure sensor. Microprocessor-based electronics provide higher spanturndown ratio, improved temperature and pressure compensation, and improved accuracy. The transmitter’s meter body and electronics housing resist shock, vibration, corrosion, and moisture. The electronics housing contains a compartment for the singleboard electronics, which is isolated from an integral junction box. The single-board electronics is replaceable and interchangeable with any other ST 3000 Series 100 or Series 900 model transmitters. Like other Honeywell transmitters, the ST 3000 features two-way communication and configuration capability between the operator and the transmitter through several Honeywell field-rated portable configuration devices, including the Smart Field Communicator (SFC) and the Multiple Communication Configurator (MC ToolKit). While both are made for in-field use, the MC Toolkit also can be ordered for use in intrinsically safe environments. The SCT 3000 Smartline® Configuration Toolkit provides an easy way to configure instruments using a personal computer. The toolkit enables configuration of devices before shipping or installation. The SCT 3000 can operate in the offline mode to configure an unlimited number of devices. The database can then be loaded down-line during commissioning.

Features
 Choice of linear or square root output conformity is a simple configuration selection.
 Direct digital integration with Experion PKS and other control systems provides local measurement accuracy to the system level without adding typical A/D and D/A converter inaccuracies.
 Unique piezoresistive sensor automatically compensates input for temperature and static pressure. Added “smart” features include configuring lower and upper range values, simulating accurate analog output, and selecting preprogrammed engineering units for display.
 Smart transmitter capabilities with local or remote interfacing means significant manpower efficiency improvements in commissioning, start-up, and ongoing maintenance functions.


Advanced Diagnostics
ST 3000 is now available for both HART® 6 and FoundationTM Fieldbus with advanced diagnostics that minimize unplanned plant outages, minimize maintenance costs and by providing the industry’s most reliable transmitter.
 Provide advanced warning of possible failure events and avoid costly shutdowns.
 Three levels of failure reporting
 Comprehensive list of on-board diagnostics (Ref. ST 3000 User manual with HART® 6, 34-ST-25-17 Rev: June 09 and FoundationTM Fieldbus option manual 34-ST-25-15 Rev: June 09)

View Product Catalog

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).