Image

Kromschroder BCU 460W3P1C0D0000K1E1-/LM400WF0O0E1- Burner Control Unit Part no 88680127 is an on-site mountable unit designed for the precise control, ignition, and monitoring of gas burners, accommodating impulse-controlled, modulating, or stage-controlled applications. It operates continuously with ionization control or UV control using the Kromschroder UV sensor UVD, and intermittently with the UV sensor UVS.

Features:

  • Burner control unit, Series 400, for gas burners
  • On-site mountable housing for impulse-controlled, modulating, or stage-controlled applications
  • Continuous operation with ionization control or UV control using Kromschroder UV sensor UVD
  • Intermittent operation with UV sensor UVS
  • Display of program status, unit parameters, and flame signal
  • Manual operating mode for flexibility
  • Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft
  • EC-type tested and certified, FM and EAC approved
  • Certified for systems up to SIL 3 (compliant with PL e)
  • Standard version with 230 V AC, 50/60 Hz mains voltage
  • Ignition transformer: 8 kV, 12 mA, ED 100%
  • Flange plate: standard
  • Valve proving system: none
  • High-temperature operation: none
  • Input function: none
  • Pressure switch: none
  • Connection plugs with screw terminals for easy installation
  • Energy supply via L1
  • Power module included
  • Air actuator: none
  • Optional output: none
  • Flame control: ionization
  • Various functions for contacts and terminals for comprehensive control
  • Burner application: burner 1
  • Safety features including flame simulation check and safety interlocks
  • Extensive configuration options for burner start-up, safety times, and operation modes
  • Fieldbus communication: Off
  • Kromschröder Safety Link: Off


Type: Burner control unit
Housing for on-site mounting, for controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. For continuous operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified for systems up to SIL 3 (compliant with PL e).
Series: Standard version
Mains voltage: 230 V AC, 50/60 Hz
Ignition transformer: 8 kV, 12 mA, ED 100 %
Flange plate: Standard
Valve proving system: None
High temperature operation: None
Input function: None
Pressure switch: None
Connection plugs: With screw terminals
Packaging: Individual packaging
Energy supply: Via L1
Power module: Power module
Series: 400
Mains voltage: 230 V AC, 50/60 Hz
Air actuator: None
Optional output: None
Energy supply: Via L1
I004 Flame control: Ionization
I050 Function of contact 80, 81/82: Fault signal
I052 Function of contact 95/96: Burner 1 operating signal
I053 Function of contact 95/97: Burner 1 operating signal
I061 Function of terminal 1: Start 1
I062 Function of terminal 2: Reset
I068 Function of terminal 35: Safety interlocks
A001 Switch-off threshold, burner 1: 2 micro A
A003 Flame simulation check: In standby position
A007 Burner 1 start-up attempts: 1
A093 Pre-ignition time tVZ: 0 s
A094 1st safety time on start-up: 3 s
A095 Flame proving period 1 tFS1: 2 s
A078 Burner application: Burner 1
A076 Function of V5: Off
A009 Restart: No
A074 Combustion mode: Flame mode
A043 Over-run: Off
A039 Over-run time: 0 s
A019 Safety time during operation: 1 s
A061 Minimum burner on time tB: 0 s
A062 Minimum pause time tMP: 0 s
A067 Operating time in Manual mode: Limited to 5 min.
A087 Purge (bus): Off
A080 Fieldbus communication: Off
A081 Kromschröder Safety Link: Off

Commodity code: 85371098
Country of origin: DE

Kromschroder BCU 460W3P1C0D0000K1E1-/LM400WF0O0E1- Burner Control Unit Part no 88680127 is an on-site mountable unit designed for the precise control, ignition, and monitoring of gas burners, accommodating impulse-controlled, modulating, or stage-controlled applications. It operates continuously with ionization control or UV control using the Kromschroder UV sensor UVD, and intermittently with the UV sensor UVS.

Features:

  • Burner control unit, Series 400, for gas burners
  • On-site mountable housing for impulse-controlled, modulating, or stage-controlled applications
  • Continuous operation with ionization control or UV control using Kromschroder UV sensor UVD
  • Intermittent operation with UV sensor UVS
  • Display of program status, unit parameters, and flame signal
  • Manual operating mode for flexibility
  • Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft
  • EC-type tested and certified, FM and EAC approved
  • Certified for systems up to SIL 3 (compliant with PL e)
  • Standard version with 230 V AC, 50/60 Hz mains voltage
  • Ignition transformer: 8 kV, 12 mA, ED 100%
  • Flange plate: standard
  • Valve proving system: none
  • High-temperature operation: none
  • Input function: none
  • Pressure switch: none
  • Connection plugs with screw terminals for easy installation
  • Energy supply via L1
  • Power module included
  • Air actuator: none
  • Optional output: none
  • Flame control: ionization
  • Various functions for contacts and terminals for comprehensive control
  • Burner application: burner 1
  • Safety features including flame simulation check and safety interlocks
  • Extensive configuration options for burner start-up, safety times, and operation modes
  • Fieldbus communication: Off
  • Kromschröder Safety Link: Off


Type: Burner control unit
Housing for on-site mounting, for controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. For continuous operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified for systems up to SIL 3 (compliant with PL e).
Series: Standard version
Mains voltage: 230 V AC, 50/60 Hz
Ignition transformer: 8 kV, 12 mA, ED 100 %
Flange plate: Standard
Valve proving system: None
High temperature operation: None
Input function: None
Pressure switch: None
Connection plugs: With screw terminals
Packaging: Individual packaging
Energy supply: Via L1
Power module: Power module
Series: 400
Mains voltage: 230 V AC, 50/60 Hz
Air actuator: None
Optional output: None
Energy supply: Via L1
I004 Flame control: Ionization
I050 Function of contact 80, 81/82: Fault signal
I052 Function of contact 95/96: Burner 1 operating signal
I053 Function of contact 95/97: Burner 1 operating signal
I061 Function of terminal 1: Start 1
I062 Function of terminal 2: Reset
I068 Function of terminal 35: Safety interlocks
A001 Switch-off threshold, burner 1: 2 micro A
A003 Flame simulation check: In standby position
A007 Burner 1 start-up attempts: 1
A093 Pre-ignition time tVZ: 0 s
A094 1st safety time on start-up: 3 s
A095 Flame proving period 1 tFS1: 2 s
A078 Burner application: Burner 1
A076 Function of V5: Off
A009 Restart: No
A074 Combustion mode: Flame mode
A043 Over-run: Off
A039 Over-run time: 0 s
A019 Safety time during operation: 1 s
A061 Minimum burner on time tB: 0 s
A062 Minimum pause time tMP: 0 s
A067 Operating time in Manual mode: Limited to 5 min.
A087 Purge (bus): Off
A080 Fieldbus communication: Off
A081 Kromschröder Safety Link: Off

Commodity code: 85371098
Country of origin: DE

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).