032L1240
- Product SKU: EVR20 032L1240
- Category: Danfoss, HVAC Controls
Danfoss Solenoid Valve EVR20, 7/8" Solder NC, 032L1240 is part of the new EVR range, offering a versatile solution for various refrigeration applications. Specifically designed to replace previous Danfoss models, this valve is well-suited for use in refrigeration systems within the air conditioning and food service industry.
The EVR20 is engineered to handle additional stress factors, making it reliable for systems with rapid defrosting cycles and/or short hot gas injection cycles. Its applications include walk-in cold rooms, display freezers, refrigerators, icemakers, and ice cream machines.
Specifications:
Gross weight | 1.382 Kg |
Net weight | 1.272 Kg |
Volume | 2.975 Liter |
EAN | 5702428952811 |
Actuator system [mm] | 13.5 mm |
Ambient temperature | -40 - 80 °C |
Ambient temperature range [°F] [max] | 175 °F |
Ambient temperature range [°F] [min] | -40 °F |
Approval | UL EAC LLC CDC EURO-TYSK |
Coil | No |
Cv value [gal/min] | 6.9 gal/min |
Direction | Straightway |
Fluid Group | 1 2 |
Function | NC |
Identical product | 032L5092 |
In scope of WEEE and contain batteries | No |
Inlet connection type | Solder, ODF |
Inlet size [in] | 7/8 in |
Kv value [m³/h] | 6 m³/h |
Lubricants compatibility | AB PAG PAO POE PVE MO |
Manual operation option | No |
Max. Working Pressure [bar] | 45.2 bar |
Max. Working Pressure [psig] | 655 psig |
MaxOPD[bar] 10W AC | 38 bar |
MaxOPD[bar] 20W DC | 20 bar |
MaxOPD[bar] coil BJ/BX | 38 bar |
MaxOPD[psi] 10W AC | 550 psi |
MaxOPD[psi] 20W DC | 290 psi |
MaxOPD[psi] coil BJ/BX | 550 psi |
Medium temp. range note | Defrost max 130°C/265°F |
Medium temperature range [°C] [max] | 105 °C |
Medium temperature range [°C] [min] | -40 °C |
Medium temperature range [°F] [max] | 221 °F |
Medium temperature range [°F] [min] | -40 °F |
MinODP [bar] | 0.03 bar |
MinODP [psi] | 0.44 psi |
MOPD[bar/psi] | Coil Dependend |
MWP [bar] PED compliant | 49 bar |
Orifice size [mm] | 22 mm |
Outlet connection type | Solder, ODF |
Outlet size [in] | 7/8 in |
Packing format | Multi pack |
Parts Program name | EVR |
PED category | Art. 4, par. 3 |
Product accessories | Solenoid valve accessories |
Product group | Solenoid valves |
Product Name Description | Solenoid valve |
Quantity per packing format | 6 pc |
REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
Refrigerants | R1234yf R125 R134a R152a R22 R290 R32 R404A R407A R407C R407F R410A R417A R448A R449A R450A R452A R600 R600a R513A R452B R454B R1234ze(E) R407H R413A R422A R422B R422D R438A R444B R447A R449B R454C R455A R463A R513B R515A R515B R516A R442A R447B R512A R454A R507A |
SCIP dossier no. | 7d4d3ef3-e2d2-40aa-a84a-0a3286c91c98 |
SCIP dossier product name | EVR 2-8/EVO 100-102 (NC) |
Serviceable | Solenoid valve spare parts |
Type | EVR 20 |
Type designation | Solenoid valve, Solder |
UL approved refrigerants | R125 R134a R152a R22 R404A R407A R407C R407F R407H R410A R413A R417A R422A R422B R422D R438A R442A R447A R447B R448A R449A R449B R450A R452A R455A R463A R507A R512A R513A R513B R515A R515B R516A R290 R600 R600a |
Valve operation | Servo-diaphragm |
Ordering Code:
EVR V2 type | Kv value [m³/h] | Opening differential pressure with standard coil ∆p [bar] | ||
Min. | Max. (= MOPD) liquid | |||
AC coil [10 W] | DC coil [20 W] | |||
EVR 2 NC | 0.15 | 0 | 38 | 33 |
EVR 3 NC | 0.26 | 0 | 38 | 18 |
EVR 4 NC | 0.7 | 0.03 | 38 | 28 |
EVR 6 NC | 1 | 0.03 | 38 | 28 |
EVR 6 NO | 1 | 0.03 | 21 | 21 |
EVR 8 NC | 1.15 | 0.03 | 38 | 28 |
EVR 10 NC | 1.47/2.2 | 0.03 | 38 | 20 |
EVR 10 NO | 2.2 | 0.03 | 21 | 21 |
EVR 15 NC | 3.3 | 0.03 | 38 | 20 |
EVR 15 NO | 3.3 | 0.03 | 21 | 21 |
EVR 18 NC | 3.9 | 0.03 | 38 | 20 |
EVR 20 NC | 6 | 0.03 | 38 | 20 |
EVR 20 NO | 6 | 0.03 | 19 | 19 |
EVR 22 NC | 6 | 0.03 | 38 | 20 |
EVR 22 NO | 6 | 0.03 | 19 | 19 |
EVR 25 NC | 9.8 | 0.2 | 38 | 17 |
EVR 32 NC | 16.7 | 0.2 | 38 | 17 |
EVR 40 NC | 24.2 | 0.2 | 38 | 17 |
Danfoss Solenoid Valve EVR20, 7/8" Solder NC, 032L1240 is part of the new EVR range, offering a versatile solution for various refrigeration applications. Specifically designed to replace previous Danfoss models, this valve is well-suited for use in refrigeration systems within the air conditioning and food service industry.
The EVR20 is engineered to handle additional stress factors, making it reliable for systems with rapid defrosting cycles and/or short hot gas injection cycles. Its applications include walk-in cold rooms, display freezers, refrigerators, icemakers, and ice cream machines.
Specifications:
Gross weight | 1.382 Kg |
Net weight | 1.272 Kg |
Volume | 2.975 Liter |
EAN | 5702428952811 |
Actuator system [mm] | 13.5 mm |
Ambient temperature | -40 - 80 °C |
Ambient temperature range [°F] [max] | 175 °F |
Ambient temperature range [°F] [min] | -40 °F |
Approval | UL EAC LLC CDC EURO-TYSK |
Coil | No |
Cv value [gal/min] | 6.9 gal/min |
Direction | Straightway |
Fluid Group | 1 2 |
Function | NC |
Identical product | 032L5092 |
In scope of WEEE and contain batteries | No |
Inlet connection type | Solder, ODF |
Inlet size [in] | 7/8 in |
Kv value [m³/h] | 6 m³/h |
Lubricants compatibility | AB PAG PAO POE PVE MO |
Manual operation option | No |
Max. Working Pressure [bar] | 45.2 bar |
Max. Working Pressure [psig] | 655 psig |
MaxOPD[bar] 10W AC | 38 bar |
MaxOPD[bar] 20W DC | 20 bar |
MaxOPD[bar] coil BJ/BX | 38 bar |
MaxOPD[psi] 10W AC | 550 psi |
MaxOPD[psi] 20W DC | 290 psi |
MaxOPD[psi] coil BJ/BX | 550 psi |
Medium temp. range note | Defrost max 130°C/265°F |
Medium temperature range [°C] [max] | 105 °C |
Medium temperature range [°C] [min] | -40 °C |
Medium temperature range [°F] [max] | 221 °F |
Medium temperature range [°F] [min] | -40 °F |
MinODP [bar] | 0.03 bar |
MinODP [psi] | 0.44 psi |
MOPD[bar/psi] | Coil Dependend |
MWP [bar] PED compliant | 49 bar |
Orifice size [mm] | 22 mm |
Outlet connection type | Solder, ODF |
Outlet size [in] | 7/8 in |
Packing format | Multi pack |
Parts Program name | EVR |
PED category | Art. 4, par. 3 |
Product accessories | Solenoid valve accessories |
Product group | Solenoid valves |
Product Name Description | Solenoid valve |
Quantity per packing format | 6 pc |
REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
Refrigerants | R1234yf R125 R134a R152a R22 R290 R32 R404A R407A R407C R407F R410A R417A R448A R449A R450A R452A R600 R600a R513A R452B R454B R1234ze(E) R407H R413A R422A R422B R422D R438A R444B R447A R449B R454C R455A R463A R513B R515A R515B R516A R442A R447B R512A R454A R507A |
SCIP dossier no. | 7d4d3ef3-e2d2-40aa-a84a-0a3286c91c98 |
SCIP dossier product name | EVR 2-8/EVO 100-102 (NC) |
Serviceable | Solenoid valve spare parts |
Type | EVR 20 |
Type designation | Solenoid valve, Solder |
UL approved refrigerants | R125 R134a R152a R22 R404A R407A R407C R407F R407H R410A R413A R417A R422A R422B R422D R438A R442A R447A R447B R448A R449A R449B R450A R452A R455A R463A R507A R512A R513A R513B R515A R515B R516A R290 R600 R600a |
Valve operation | Servo-diaphragm |
Ordering Code:
EVR V2 type | Kv value [m³/h] | Opening differential pressure with standard coil ∆p [bar] | ||
Min. | Max. (= MOPD) liquid | |||
AC coil [10 W] | DC coil [20 W] | |||
EVR 2 NC | 0.15 | 0 | 38 | 33 |
EVR 3 NC | 0.26 | 0 | 38 | 18 |
EVR 4 NC | 0.7 | 0.03 | 38 | 28 |
EVR 6 NC | 1 | 0.03 | 38 | 28 |
EVR 6 NO | 1 | 0.03 | 21 | 21 |
EVR 8 NC | 1.15 | 0.03 | 38 | 28 |
EVR 10 NC | 1.47/2.2 | 0.03 | 38 | 20 |
EVR 10 NO | 2.2 | 0.03 | 21 | 21 |
EVR 15 NC | 3.3 | 0.03 | 38 | 20 |
EVR 15 NO | 3.3 | 0.03 | 21 | 21 |
EVR 18 NC | 3.9 | 0.03 | 38 | 20 |
EVR 20 NC | 6 | 0.03 | 38 | 20 |
EVR 20 NO | 6 | 0.03 | 19 | 19 |
EVR 22 NC | 6 | 0.03 | 38 | 20 |
EVR 22 NO | 6 | 0.03 | 19 | 19 |
EVR 25 NC | 9.8 | 0.2 | 38 | 17 |
EVR 32 NC | 16.7 | 0.2 | 38 | 17 |
EVR 40 NC | 24.2 | 0.2 | 38 | 17 |
Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.
Cancellations :
– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.
Return Policy :
If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.
Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:
- Any product that exhibits physical damage to the box or to the product;
- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;
- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;
- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;
Replacements :
– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.
– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.
- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same
- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.
Refund :