Honeywell T+Rh Trasmitter (Wall Mounnt) - RHP-W
Categories
  • Same day Shipment
    for stock items
  • 100% Customer
    Satisfaction
  • 365 Days
    Support on Call
  • Payment
    Secure System
  • Only Best
    Brands

Honeywell T+Rh Trasmitter (Wall Mounnt) - RHP-W

Available: Out of Stock
Rs. 1.00
Successful pre-order.Thanks for contacting us!
Secure

SPECIFICATIONS:

Relative Humidity Range: 0 to 100% RH.
Temperature Range: -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors.
   -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors.
Dew Point Temperature Range: -20 to 140°F (-28.9 to 60°C); 0 to 100°F
   (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) fieldselectable
   ranges.
Accuracy:
   RH: Model RHP-2XXX ±2% 10-90% RH @ 25°C; Model RHP-3XXX ±3%
   20-80% RH @ 25°C; Model RHP-5XXX ±5% 20-80% RH @ 25°C;
Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C);
RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C);
Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C).
Hysteresis: ±1%.
Repeatability: ±0.1% typical.
Temperature Limits:
   Operating: -40 to 140°F (-40 to 60°C);
   Storage: -40 to 176°F (-40 to 80°C).
Compensated Temperature Range: -4 to 140°F (-20 to 60°C).
4-20 mA Loop Powered Outputs:
   Power requirements: 10 to 35 VDC;
   Output signal: 4 to 20 mA, 2 channels for humidity/solid state temperature
   sensor models (loop powered on RH). Switch selectable RH/dew point. Switch
   selectable normal or reverse output.
0-5/10V Outputs:
   Power Requirements: 15 to 35 VDC or 15 to 29 VAC;
v  Output Load: 5 mA max., 2 channels for humidity/solid state temperature
   sensor models. Switch selectable 0-10V/2-10V or 0-5V/1-5V output. Switch
   selectable RH/dew point. Switch selectable normal or reverse output.
Solid State Band Gap Temperature Sensor Output Ranges: Switch selectable,
   -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to
   32.3°C); -4 to 140°F (-20 to 60°C).
Response Time: 15 seconds.
Electrical Connections: Screw terminal block.
Drift: <1% RH/year.
RH Sensor: Capacitance polymer.
Enclosure Material: Warm gray polycarbonate.
Display: Optional LCD, backlit on 0-5/10V models. Switch selectable %RH or dew
   point, °F/°C.
Display Resolution: RH: 1%; Temperature: 0.1°F (0.1°C); Dew Point: 1°F (1°C).
Weight: 0.3 lb (0.14 kg).
Agency Approvals: CE.

ACCESSORIES:

1. A-449, Remote LCD Display allows remote
   indication of select Dwyer Wall Mount
   Transmitters for validation or certification
   purposes
2. SCD-PS, 100-240 VAC/VDC to 24 VDC
   Power Supply

SPECIFICATIONS:

Relative Humidity Range: 0 to 100% RH.
Temperature Range: -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors.
   -20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors.
Dew Point Temperature Range: -20 to 140°F (-28.9 to 60°C); 0 to 100°F
   (-17.8 to 37.8°C); 40 to 90°F (4.4 to 32.3°C); -4 to 140°F (-20 to 60°C) fieldselectable
   ranges.
Accuracy:
   RH: Model RHP-2XXX ±2% 10-90% RH @ 25°C; Model RHP-3XXX ±3%
   20-80% RH @ 25°C; Model RHP-5XXX ±5% 20-80% RH @ 25°C;
Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C);
RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C);
Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C).
Hysteresis: ±1%.
Repeatability: ±0.1% typical.
Temperature Limits:
   Operating: -40 to 140°F (-40 to 60°C);
   Storage: -40 to 176°F (-40 to 80°C).
Compensated Temperature Range: -4 to 140°F (-20 to 60°C).
4-20 mA Loop Powered Outputs:
   Power requirements: 10 to 35 VDC;
   Output signal: 4 to 20 mA, 2 channels for humidity/solid state temperature
   sensor models (loop powered on RH). Switch selectable RH/dew point. Switch
   selectable normal or reverse output.
0-5/10V Outputs:
   Power Requirements: 15 to 35 VDC or 15 to 29 VAC;
v  Output Load: 5 mA max., 2 channels for humidity/solid state temperature
   sensor models. Switch selectable 0-10V/2-10V or 0-5V/1-5V output. Switch
   selectable RH/dew point. Switch selectable normal or reverse output.
Solid State Band Gap Temperature Sensor Output Ranges: Switch selectable,
   -20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to
   32.3°C); -4 to 140°F (-20 to 60°C).
Response Time: 15 seconds.
Electrical Connections: Screw terminal block.
Drift: <1% RH/year.
RH Sensor: Capacitance polymer.
Enclosure Material: Warm gray polycarbonate.
Display: Optional LCD, backlit on 0-5/10V models. Switch selectable %RH or dew
   point, °F/°C.
Display Resolution: RH: 1%; Temperature: 0.1°F (0.1°C); Dew Point: 1°F (1°C).
Weight: 0.3 lb (0.14 kg).
Agency Approvals: CE.

ACCESSORIES:

1. A-449, Remote LCD Display allows remote
   indication of select Dwyer Wall Mount
   Transmitters for validation or certification
   purposes
2. SCD-PS, 100-240 VAC/VDC to 24 VDC
   Power Supply

View Product Catalog

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).