OOM102-1
Categories
  • Same day Shipment
    for stock items
  • 100% Customer
    Satisfaction
  • 365 Days
    Support on Call
  • Payment
    Secure System
  • Only Best
    Brands

OOM102-1

Available: In Stock
Rs. 3,500.00
Please wait...
Your Inquiry has been sent! Our sales representative will contact you.
Image

Envitec Medical Oxygen Sensor OOM102-1 part no. E01-00-0020

Specifications : 

Measurement Range:0-100 % oxygen
Output in ambient air:9 to 14mV
Electrical Interface:OOM102-1: 3,5mm Mono Jack
Accuracy and Repeatability:< 1 % vol. O2 when calibrated at 100 % Oxygen
Linearity error:< 3 % relative
Response time:< 12sec. to 90 % of final value
Zero Offset Voltage:< 200 μV in 100 % nitrogen applied after 5 min
Influence of Mechanical Shock:< 1% relative after a fall from 1m
Operating Temperature:0 to 50°C
Temperature Compensation : built-in NTC compensation
Effect of Temperature Compensation (steady state): between +25°C and +40°C: 3 % relative error, between 0 °C and +50 °C: 8 % relative error
Operating Humidity:0-99 % RH non-condensing
Long Term Output Drift:< 1 % vol oxygen per month typically < - 15 % relative over lifetime
Storage Temperature: -20 to +50 °C Recommended Storage:+5 to +15 °C
Recommended Load: 10 k Ohms Warm-Up Time:< 30 minutes, after replacement of sensor
Nominal Sensor Lifetime: 1.000.000 % vol oxygen hours
Weight : approximately 28 grams

Envitec Medical Oxygen Sensor OOM102-1 part no. E01-00-0020

Specifications : 

Measurement Range:0-100 % oxygen
Output in ambient air:9 to 14mV
Electrical Interface:OOM102-1: 3,5mm Mono Jack
Accuracy and Repeatability:< 1 % vol. O2 when calibrated at 100 % Oxygen
Linearity error:< 3 % relative
Response time:< 12sec. to 90 % of final value
Zero Offset Voltage:< 200 μV in 100 % nitrogen applied after 5 min
Influence of Mechanical Shock:< 1% relative after a fall from 1m
Operating Temperature:0 to 50°C
Temperature Compensation : built-in NTC compensation
Effect of Temperature Compensation (steady state): between +25°C and +40°C: 3 % relative error, between 0 °C and +50 °C: 8 % relative error
Operating Humidity:0-99 % RH non-condensing
Long Term Output Drift:< 1 % vol oxygen per month typically < - 15 % relative over lifetime
Storage Temperature: -20 to +50 °C Recommended Storage:+5 to +15 °C
Recommended Load: 10 k Ohms Warm-Up Time:< 30 minutes, after replacement of sensor
Nominal Sensor Lifetime: 1.000.000 % vol oxygen hours
Weight : approximately 28 grams

View Product Catalog

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).